              kVP表kVp Meter and Exposure Time Meter

              點擊次數:161發布時間:2011/3/17 14:09:42

              kVP表kVp Meter and Exposure Time Meter

              更新日期:2017/8/25 10:06:39

              所 在 地:美洲

              產品型號:

              簡單介紹:The ECC kVp meter and exposure timer Measures the peak x-ray accelerating voltage from tungsten x-ray generators. To measure peak kV the user simply places the instrument in the beam and takes an x-ray.

              相關標簽:kVP表 kVp Meter Exposure Time Meter 

              優質供應

              詳細內容

               kVPkVp Meter and Exposure Time Meter

               

               

              The ECC kVp meter and exposure timer Measures the peak x-ray accelerating voltage from tungsten x-ray generators. To measure peak kV the user simply places the instrument in the beam and takes an x-ray. In addition to measuring kVp, the unit also measures the exposure time and displays the x-ray waveform type. The Capintec kVp Meter can be used on radiographic, fluoroscopic  and dental x-rays.  There is a high resolution mode which is used for measurements on older x-rays and x-rays with slow rise times. The kVp Meter has a large display which is readable from outside the x-ray room.

               

               

              Features

              Small Hand Held Size

              Easy to use

              Non invasive

              High Accuracy

              Battery Operated

              Two Year Warranty

              Measures kVp and exposure time

              simultaneously

              Compact size

              Durable ABS Plastic Case

              Custom Carrying Case Option

               

              Specifications

              Range

              45 to 125 kV

              kVp Accuracy

              2% +/- 1 kV, at 25 to 100 mA

              18 to 42 cm from head, for

              Tungsten target x-ray tube with 1.5

              mm Al equivalent filtration

              Exposure Time Accuracy

              2% +/- 3 millisecond

              Minimum exposure time is 100

              millisecond

              Minimum Exposure Time (kVp

              Measurement)

              100 millisec - High Speed Mode

              (normal)

              200 millisec - High Resolution Mode

              Minimum Current (mA)

              7 mA at 50 kV, 10 cm from x-ray

              source

              Also depends on focus / collimation

              Display

              0.4"(10.2mm) Liquid Crystal

              8 Character Alphanumeric

               

               

              Power

               

              4 AA Batteries accessible from bottom

              of case

              Low Battery Indicator

              Battery Life

              48 hours continuous

              Typically 9 months of normal use

              Controls/Indicators

              ON/OFF Switch

              Illuminated push-button with green

              power-on indication

              Mode Switch

              Momentary push-button

              8 Character Liquid Crystal Display

              Oscilloscope output

              Physical Size

              150 x 120 x 58.5 mm

              5.9 x 4.7 x 2.3 inches

              Weight

              0.7 kG1.5 lb

              Connections

              None required for normal kVp

              measurement

              3.5mm Jack for Oscilloscope Output

              Optional Accessories

              Padded Cordura Carrying Case

              Oscilloscope Interface Cable 

               

               

              Typical Applications

              Measurement of Exposure

              Verification of peak x-ray voltage

              Constancy checks

              X-ray calibration

              Quality Assurance

              Measurement of X-ray Exposure Time

              Half Value Layer determination

              Troubleshooting and Repair of X-rays

               

               

               

               